Features

  • ‘Soft start’ operation
  • ‘Vout OK’ signal monitor
  • Adjustable down to 0 volts (‘Wide Adjust’ models)
  • Can be paralleled for increased current (option P)
  • Constant voltage and constant current modes
  • Internal EMI Filter and RFI Shielding
  • Low Profile
  • N+1 Redundancy (option N)
  • No minimum load required
  • Pluggable connectors for input and control wiring
  • Power Factor Correction
  • Remote Sensing
  • Short circuit and overload protection
  • Thermal protection
  • Universal input
  • Voltage and current monitor terminals
  • Voltage and current programming capabilities

Specifications

    General
  • Ambient operating temperature: 0 to +71°C
  • Dielectric Withstand Voltage: Input to output: 4242 Vdc 300 Vdc | Input to case: 2121 Vdc 300 Vdc | Output to case: 750 Vdc 300 Vdc
  • DRIFT: ±0.1% (typ) over 8 hours, after 30 minute warmup
  • Holdup Time: 20 mS minimum with full load
  • Input Voltage: 90-265 VAC, 49-420 Hz, single phase, or 110-350 Vdc. 208 VAC 3-phase | AC input (max): 8A (WL7 case), 12A(WL9 case) | DC input(max): 5.75A (WL7 case), 8.8A (WL9 case)
  • Inrush Current: Cold start, (thermistor limiter) 33A peak @ 115 VAC (typ); 65A peak @ 230 VAC (typ)
  • Internal Failure Protection: Provided by internal fuse
  • Output Inhibit: Applying between +3 and +15 Vdc to the Inhibit terminal will disable the supply | ‘Output Enable’ is also available
  • Overload/Short Circuit Protection: A short or overload forces the power supply into constant current mode with automatic recovery
  • Overvoltage Protection: Latches power supply OFF, reset by momentarily removing AC input power (Models with ‘N’ option reset automatically)
  • Polarity: Output is floating and may be used in either polarity
  • Power Factor: 0.99 typical at 115 VAC, 60Hz and full load
  • Regulation (in constant voltage mode): Line Regulation: ±0.05% or 5 mV, whichever is greater | Load Regulation: ±0.05% or 5 mV, whichever is greater
  • Ripple Regulation (in constant current mode): Line Regulation: ±0.2% or 30 mA | Load Regulation: ±0.5% or 100 mA | Current Ripple: 0.5% rms
  • Startup time: 800 mS
  • Storage Temperature: –40 to +85°C
  • Switching Frequency: 109 kHz (typ)
  • Temperature Coefficient: Voltage ±0.02%/°C (typ) | Current ±0.1%/°C (typ)
  • Thermal Protection: Thermostat(s), self-resetting
  • Transient response: 300 µS to return to ±1% of output setting | Maximum of ±3% output excursion following a load step change from 50% to 100%

 