W18LT2500 - Acopian W18LT2500 Low Profile Power Supplies. Nominal Output Voltage: 18...
Request Quote
For Price
- Part Number:
- W18LT2500
- Model Number:
- W18LT2500
- Make:
- ACOPIAN
- Lead Time:
- Available
- Qty In Stock:
- Available
Acopian W18LT2500 Low Profile Power Supplies. Nominal Output Voltage: 18 | Efficiency (Typ.) %: 75 | Case Size: WL7 | Single Output Simple Type: Power Supply
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- ‘Soft start’ operation
- ‘Vout OK’ signal monitor
- Adjustable down to 0 volts (‘Wide Adjust’ models)
- Can be paralleled for increased current (option P)
- Constant voltage and constant current modes
- Internal EMI Filter and RFI Shielding
- Low Profile
- N+1 Redundancy (option N)
- No minimum load required
- Pluggable connectors for input and control wiring
- Power Factor Correction
- Remote Sensing
- Short circuit and overload protection
- Thermal protection
- Universal input
- Voltage and current monitor terminals
- Voltage and current programming capabilities
Specifications
- Ambient operating temperature: 0 to +71°C
- Dielectric Withstand Voltage: Input to output: 4242 Vdc 300 Vdc | Input to case: 2121 Vdc 300 Vdc | Output to case: 750 Vdc 300 Vdc
- DRIFT: ±0.1% (typ) over 8 hours, after 30 minute warmup
- Holdup Time: 20 mS minimum with full load
- Input Voltage: 90-265 VAC, 49-420 Hz, single phase, or 110-350 Vdc. 208 VAC 3-phase | AC input (max): 8A (WL7 case), 12A(WL9 case) | DC input(max): 5.75A (WL7 case), 8.8A (WL9 case)
- Inrush Current: Cold start, (thermistor limiter) 33A peak @ 115 VAC (typ); 65A peak @ 230 VAC (typ)
- Internal Failure Protection: Provided by internal fuse
- Output Inhibit: Applying between +3 and +15 Vdc to the Inhibit terminal will disable the supply | ‘Output Enable’ is also available
- Overload/Short Circuit Protection: A short or overload forces the power supply into constant current mode with automatic recovery
- Overvoltage Protection: Latches power supply OFF, reset by momentarily removing AC input power (Models with ‘N’ option reset automatically)
- Polarity: Output is floating and may be used in either polarity
- Power Factor: 0.99 typical at 115 VAC, 60Hz and full load
- Regulation (in constant voltage mode): Line Regulation: ±0.05% or 5 mV, whichever is greater | Load Regulation: ±0.05% or 5 mV, whichever is greater
- Ripple Regulation (in constant current mode): Line Regulation: ±0.2% or 30 mA | Load Regulation: ±0.5% or 100 mA | Current Ripple: 0.5% rms
- Startup time: 800 mS
- Storage Temperature: –40 to +85°C
- Switching Frequency: 109 kHz (typ)
- Temperature Coefficient: Voltage ±0.02%/°C (typ) | Current ±0.1%/°C (typ)
- Thermal Protection: Thermostat(s), self-resetting
- Transient response: 300 µS to return to ±1% of output setting | Maximum of ±3% output excursion following a load step change from 50% to 100%
Applications
- None Available
Aliases