Acopian RWL12G7 Redundant Power Packages. Wall Mounting Models. AC-DC Single Output. | Nominal Output Voltage: 12 | Adjust Range Voltage: 0.5 | Case Size: 522RW17 Simple Type: Power Supply

An Acopian Redundant Power Package is installed by simply connecting the AC input and DC output terminals. All wiring (including isolation diodes, output monitor circuits, switches, meters, adjustments and connectors) has been done for you.

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • All Acopian Redundant Power Packages may be operated with only one AC power source. However, two isolated sets of AC input connections are provided, so that two independent sources of input power may
  • Each Redundant Power Package contains two identical power supplies with their outputs interconnected through a diode switching arrangement that will detect any fault condition, isolate it from the sys

Specifications

    General
  • Alarm Relay Contact Ratings: 120 VAC, 8A / 60 Vdc, 1A. (To comply with SELV requirements, limit switched voltage to 60 Vdc / 42 VAC.)
  • Ambient Operating Temperature: 0 to +71°C.
  • Backup mode: 0.2 volts less than nominal voltage shown in table.
  • Input Voltage: 90-132 VAC, 49-61 Hz, single phase. For models R24W7, RWL24W7, R28W7, RWL28W7, R48W7 and RWL48W7, the use of 30A lines is recommended. When operating on 50 Hz input, derate output by 5%.
  • Line Regulation: ±0.05%
  • Load Protection: Overvoltage protection.
  • Load Regulation: ±0.05% (Dynamic regulation - does not include 0.2 volt shift which occurs during switchover to lower-set backup supply.)
  • Output Metering: Two voltmeters (standard). Ammeters available; see Options.
  • Output Voltage Adjustment Range: ±0.5 volt minimum.
  • Overload/Short Circuit Protection: Foldback current limiting with automatic recovery.
  • Polarity: Output is floating; either positive or negative output terminal may be grounded or floated up to 300 volts above ground.
  • Remote Voltage Sensing: Provision for sensing the output voltage across the load, so that drops in the load line are compensated, is a standard feature.
  • Ripple: 15 mV rms, 100 mV p-p. (48 volt outputs;25 mV rms, 150 mV p-p.)
  • Storage Temperature: -40 to +85°C.
  • Temperature Coefficient: 0.02%/°C (Typical)
  • Terminal Strip Cover: Clips on.
  • Voltage Monitor Circuits: One for each power supply. Relay contacts switch when output voltage decreases approximately 2 volts from the nominal rating (approximately 3 volts for outputs over 48 volts), and may be used to control an external failure alarm.

 

Applications

  • Redundant Power Packages should be considered for any equipment where the highest attainable reliability is essential, and an unexpected loss of power would be disastrous. Such applications include co