ACOPIAN Industrial Partner

RWL120M6 - Acopian RWL120M6 Redundant Power Packages. Wall Mounting Models. Power Supplies. Nominal Output ...

larger image

Request Quote
For Price
Part Number:
RWL120M6
Model Number:
RWL120M6
Make:
ACOPIAN
Lead Time:
Available
Qty In Stock:
Available

Acopian RWL120M6 Redundant Power Packages. Wall Mounting Models. Power Supplies. Nominal Output ±V: 120 | Adjust Range: 1 | Case Size: 517R18 | Wall Mounting Models Simple Type: Power Supply

An Acopian Redundant Power Package is installed by simply connecting the AC input and DC output terminals. All wiring (including isolation diodes, output monitor circuits, switches, meters, adjustments and connectors) has been done for you.

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • A separate set of AC input terminals is provided for reach power supply, so that if two sources of AC input power are available,one may be used for each supply and so reduce the possibility of output

Specifications

    General
  • Alarm Relay Contact Ratings: 120VAC,8A/60Vdc,1A (To comply with SELV requirements,limit switched voltage to 60Vdc/42VAC.)
  • Ambient Operating Temp. Linear: –20 to +71°C.
  • Ambient Operating Temp. Switching: 0 to +71°C
  • Input Voltage: (A separate set of AC input terminals is provided for each power supply, so that if two sources of AC input power are available, one may be used for each supply and so reduce the possibility of out put dropout due to loss of input power.)
  • Linear: –20 to +71°C.
  • Linear: –55 to +85°C.
  • Linear (all models): 105-125 VAC, 50-400 Hz, single phase.
  • Modular Redundant Systems: ‘OutputPresent’ LED for each power supply is located on the Integration Module.(‘Output Present’ green LEDs are also located on each power supply (DC on) on the Switching Regulated Modular Redundant Systems.)
  • Overload/Short Circuit Protection: Foldback current limiting with automatic recovery (Switching Modular Redundant
  • Polarity: Output is floating; either positive or negative output terminal may be grounded or floated up to 300 volts above ground.
  • Polarity: Output is floating; either positive or negative output terminal may be grounded orfloated up to 300 volts above ground.
  • Redundant Power Packages: A separate volt meter for each output(standard). Am meters available; see Options.
  • Remote Voltage Sensing: Provision for sensing the output voltage across the load, so that drops in the load lines are compensated, is a standard feature.
  • Storage Temp. Linear: –55 to +85°C.
  • Switching: –40 to +85°C.
  • Switching: 0 to +71°C.
  • Switching (Modular Redundant Systems): 90-265 VAC, 49-420 Hz, single phase.
  • Switching (Pluggable Redundant Power Packages): 90-265 VAC, 49-420 Hz, single phase.
  • Switching (Redundant Power Packages): 90-132 VAC, 49-61 Hz, single phase.
  • Temperature Coefficient: 0.02%/°C (Typical)
  • Temperature Coefficient: 0.02%/°C (Typical).
  • Terminal Strip Cover: Clips on

 

Applications

  • Computer; High Voltage; Instrumentation; Laser; Magnetic; Semiconductor / Thin Film; Telecommunications; Testing Equipment; Communication Systems, Process Controls

Aliases

  • None Available