ACOPIAN Industrial Partner

RM120N8T - Acopian RM120N8T Linear Regulated. Modular Redundant Systems. Nominal Output Voltage: 120 | Adjust Nominal Range...

larger image

Request Quote
For Price
Part Number:
RM120N8T
Model Number:
RM120N8T
Make:
ACOPIAN
Lead Time:
Available
Qty In Stock:
Available

Acopian RM120N8T Linear Regulated. Modular Redundant Systems. Nominal Output Voltage: 120 | Adjust Nominal Range ±V : 1 | Integration Module: RM6 | Case Size: CN8T Simple Type: Power Supply

Each Modular Redundant DC Power System consists of three units: two identical power supplies connected to an Integration Module by 24” long cables. The Integration Module includes the diodes for isolating the power supply outputs ,AC input switches, input fuses, LED‘output present’ indicators,failure alarm circuits, and the umbilical cables which plug into the power supplies. Connections for the AC inputs, redundant DC output and failure alarm relays are on a screw terminal strip.

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • AC-DC Single Output
  • Another benefit is that the three modules need not be mounted together, so that if a control panel is crowded, just the integration Module may be mounted there and the power supplies mounted elsewhere
  • These systems have the versatility to be mounted in a wide variety of ways within a system cabinet, on a DIN rail or to a wall.

Specifications

    General
  • Ambient Operating Temp. Linear: –20 to +71°C.
  • Ambient Operating Temp. Switching: 0 to +71°C
  • Input Voltage: (A separate set of AC input terminals is provided for each power supply, so that if two sources of AC input power are available, one may be used for each supply and so reduce the possibility of out put dropout due to loss of input power.)
  • Linear (all models): 105-125 VAC, 50-400 Hz, single phase.
  • Polarity: Output is floating; either positive or negative output terminal may be grounded or floated up to 300 volts above ground.
  • Remote Voltage Sensing: Provision for sensing the output voltage across the load, so that drops in the load lines are compensated, is a standard feature.
  • Storage Temp. Linear: –55 to +85°C.
  • Switching (Modular Redundant Systems): 90-265 VAC, 49-420 Hz, single phase.
  • Switching (Pluggable Redundant Power Packages): 90-265 VAC, 49-420 Hz, single phase.
  • Switching (Redundant Power Packages): 90-132 VAC, 49-61 Hz, single phase.
  • Temperature Coefficient: 0.02%/°C (Typical)

 

Applications

  • None Available

Aliases