ACOPIAN Industrial Partner

RM10WN8 - Acopian RM10WN8 Modular Redundant Systems. AC-DC Single Output. Nominal Output Voltage: 10 | Adjust Range ±V: 0.5 | Integration...

larger image

Request Quote
For Price
Part Number:
RM10WN8
Model Number:
RM10WN8
Make:
ACOPIAN
Lead Time:
Available
Qty In Stock:
Available

Acopian RM10WN8 Modular Redundant Systems. AC-DC Single Output. Nominal Output Voltage: 10 | Adjust Range ±V: 0.5 | Integration Module: RW6 | Case sizes: WN8 | Switching Regulated. Simple Type: Power Supply

Each Modular Redundant DC Power System consists of three units: two identical power supplies connected to an Integration Module by 24” long cables. The Integration Module includes the diodes for isolating the power supply outputs,AC input switches, input fuses, LED ‘output present’ indicators, failure alarm circuits, and the umbilical cables which plug into the power supplies. Connections for the AC inputs, redundant DC output and failure alarm relays are on a screw terminal strip Extremely high overall reliability results from connecting two power sources so that one will continue to provide power to their load even if the other becomes inoperative. Redundancy may be restored by replacing or repairing the inoperative source while the system remains in operation. A redundant power system should be used whenever the highest attainable reliability is essential, as in communications, computer systems (data storage in particular), process controls, utility and municipal systems, and security/safety systems.

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • None Available

Specifications

    General
  • Cooling: Forced-air cooled; air enters rear of power supply and exits from top.
  • Drift: ±0.1% typical over 8 hours, after 30 minute warmup.
  • Holdup Time: 16 mS minimum.
  • Input Voltage: 90-265 VAC, 49-420 Hz, single phase.(A separate set of AC input terminals is provided for each power supply, so that if two sources of AC input power are
  • Inrush current: Cold start, (thermistor limiter) 20A peak @115 VAC; 40A peak @ 230 VAC.
  • Isolation: Input to output, input to case; 300 Vdc. Output to case; 300 Vdc.
  • Output Monitoring: ‘Output Present’ green LEDs are located on each power supply (DC on) and on the Integration Module.
  • Power Factor: 0.99 typical at 115 VAC, 60Hz and full load. Complies with EN61000-3-2.
  • Remote Sensing: Compensates up to 0.5 volt drop per output line (1 volt for 55 to 125 volt models), within the limits of the output voltage adjustment range.
  • Startup Time: 800 mS typical.
  • Switching Frequency: 100 kHz (Typical).
  • Thermal Protection: Thermostat, self-resetting.
  • Transient Response: 300 µS to return to ±1% of output setting. Maximum of ±3% output excursion following a load step change from 50% to 100%.

 

Applications

  • Computer; High Voltage; Instrumentation; Laser; Magnetic; Semiconductor / Thin Film; Telecommunications; Testing Equipment; Communication Systems, Process Controls

Aliases

  • None Available