A06HX1200 - Acopian A06HX1200 Power Supplies. Gold Box | Voltage Prgmg. Fixed...
Request Quote
For Price
- Part Number:
- A06HX1200
- Model Number:
- A06HX1200
- Make:
- ACOPIAN
- Lead Time:
- Available
- Qty In Stock:
- Available
Acopian A06HX1200 Power Supplies. Gold Box | Voltage Prgmg. Fixed Current Limiting | Case Size: H11 | Output Voltage Range: 0-6 | Voltage Prgmg. Coeff. (Ω/V): 820 Simple Type: Power Supply
These power supplies have the broad adjustment capability required for analog instrumentation and circuitry, electronic system development, basic research, and similar applications. For applications requiring a constant current or adjustable current limiting, a power supply with a true constant-current characteristics, such as those with model numbers beginning with the letter 'P' should be used. Threaded mounting holes permit mounting to a chassis, cabinet wall or bracket. To mount from the power supply side of the mounting surface or for DIN rail mounting.
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- Overvoltage Protection
- Remote Voltage Programming
- Remote Voltage Sensing
- Voltage Programmable Adjustable Current Limiting for models starting with 'P'
- Voltage Programmable Fixed Current Limiting for models starting with 'A'
Specifications
- Ambient operating temperature: -20 to +71°C
- Current limiting: Models with fixed current limiting have a rolloff characteristic with automatic recovery. All others have current limiting with a constant-voltage/constant-current crossover characteristic
- Input Voltage: 105-125 VAC, 50-400 Hz, single phase
- Line Regulation: ±0.005% or 2 mV, whichever is greater
- Line Regulation: ±0.1% or 2 mA
- Load Regulation: ±0.005% or 2 mV, whichever is greater
- Load Regulation: ±0.2% or 5 mA
- Polarity: Output is floating, either positive or negative terminal may be grounded or floated up to 300 volts above ground
- Remote Voltage Programming: The output voltage of all models may be controlled by means of external resistance connected in series with the -S lead
- Remote Voltage Sensing: Provision for sensing the output voltage across the load, to compensate voltage drops in output wiring, is a standard feature
- Ripple: 0.1% rms
- Ripple: 0.25mV rms
- Storage Temperature: -55 to +85°C
- Temperature Coefficient (constant voltage mode): 0.015%/°C (typical)
- Voltage Programming Coefficient: Calibration tolerance ±2%
Applications
- None Available
Aliases