Acopian L13.8MC400 Single Output Power Supplies. Nominal Output Voltage: 13.8 | Adjust Range ± V: 1 | Case Size: LM6A Simple Type: Power Supply

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • Can be mounted on two surfaces in any orientation
  • Highly configurable options
  • Internal EMI Filtering
  • Isolated output
  • No minimum load required
  • Open Sense protection
  • Pluggable connectors
  • Remote Sensing
  • Short circuit and overload protection with enhanced surge capabilities
  • Slot voltage available from 1.5v to 150v

Specifications

    General
  • AC Input Current (maximum): 1.3A (LM6A case), 2A (LM8A case), 3A(LM10Acase)
  • Altitude Rating: operation to 10,000 ft and storage to 40,000 ft
  • Ambient Operating Temperature: –20 to +71°C
  • Cooling: Forced-air cooled; air enters rear of power supply and exits from front cover.
  • Dielectric Withstand Voltage: Input to output: 4242 Vdc; Isolation Vdc | Input to case: 2121 Vdc; Isolation 500 VAC | Output to case: 750 Vdc; Isolation 300 VAC
  • Drift, LongTerm (@ 25°C): Voltagemode;±0.01%or5mv,whicheverisgreater,over8hours. Voltage mode; ±0.015% or 10 mv, whichever is greater, over 1000 hours | Current mode (Wide Adjust models); ±0.01% or 5 ma, whichever is greater, over 8 hours. Current mode (Wide Adjust models); ±0.02% or 10 ma, whichever is greater, over 1000 hours.
  • Drift, Warm-up (first 30 minutes after turn-on,@ 25°C): Voltage mode; ±0.03% or 5 mv, whichever is greater. Current mode (Wide Adjust models); ±0.01% or 10 ma, whichever is greater
  • Input Undervoltage: An input of less than 105VAC will not damage power supply
  • Input Voltage: 105-125 VAC, 50-420 Hz, single phase. (100-132 VAC, 60Hz with 30% derating.)
  • Internal Failure Protection: Provided by internal fuse
  • Mounting: Threaded mounting holes permit mounting to a chassis, cabinet wall or bracket. To mount from the power supply side of the mounting surface use MountingKitGB8 or GBR. For DIN rail mounting use Mounting Kit LH35DIN or LR35DIN.
  • Output Voltage Adjustment: Screwdriver accessible
  • Polarity: Output is floating; either positive or negative terminal may be grounded or floated up to 300 volts above ground. Optional controls and monitors are referenced to the negative terminal
  • Regulation, Ripple (in constant current mode): (WideAdjust Output models) Line Regulation: ±0.01% or 2 mA, whichever is greater | Load Regulation: ±0.01% or 2 mA, whichever is greater. Current Ripple: 0.25% rms
  • Remote Sensing: Provision for sensing the output voltage across the load, so that drops in the load line are compensated, is a standard feature. Compensates up to 0.5 Vdc drop per output line (or within the limits of the output voltage adjustment range). (Wide Adjust Output models compensate up to 0.5 Vdc drop per output line.)
  • Short Circuit and Overload Protection: A short or overload forces the power supply into foldback protection, (SingleOutput models) orinto constant current mode (Wide Adjust Output models), with automatic recovery.
  • Start-up Surge: 15% overcurrent for 500ms surge capability (Single Output models)
  • Start-up Time: 75 to 150 msec
  • Storage Temperature: –55 to +85°C
  • Temperature Coefficient (after 30 minute warm-up): Voltage mode; ±0.01%/°C (typical) | Current mode (WideAdjust models); ±0.005%/°C (typical)
  • Transient Response: 300 µS to return to ±1% of output setting. Maximum of ±3% output excursion following a load step change from 50% to 100%
  • Turn-off: Exponentially decays to zero

 