Acopian 48C32FT370 Converters. Narrow Profile DC-DC Converters | 36 to 75 Vdc Input | Case Size: DN6A | Nominal Output Voltage: 32 | Adjust Range ±V: 1 Simple Type: DC/DC Converter

These state-of-the-art DC-DC converters combine excellent regulation and ripple specifications with broad input ranges. They are available in a large selection of output voltages and current ratings.

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • Extensive filtering and shielding
  • Extruded aluminum case
  • Input/output isolation exceeds 2828Vdc
  • Output status indicator
  • Tight regulation, low ripple

Specifications

    General
  • Ambient OperatingTemperature: 0 to +71°C
  • Cooling: (Case sizes DN8, DN8A, DN6A) forced-air cooled; air enters rear of power supply and exits from top | (Case size DN6B) convection cooled
  • DRIFT: ±0.1% typical over 8 hours | after 30 minute warmup
  • Efficiency: (Typical, at nominal input voltage, with full load) 65 to 80%
  • Input Reverse Polarity Protection: Internal shunt diode (external fuse required)
  • Output Indicator (DC out): Green LED
  • Output Inhibit (DN8 and DN8A case sizes only): Applying between +3 and +25 Vdc (relative to the – Out terminal) to the inhibit terminal will disable the supply
  • Output Voltage Remote Adjustment: The output voltage may be controlled by means of an external 1K potentiometer
  • Overload/Short Circuit Protection: Current limiting with automatic recovery
  • Overvoltage Protection: (Case sizes DN6A & DN6B) automatic reset | (Case sizes DN8 & DN8A) latches power supply OFF, reset by momentarily removing DC input power
  • Polarity: Output is floating and may be used in either polarity
  • REGULATION: (Line) ±0.05% | (Load) ±0.05%
  • Remote Sensing: Compensates up to 0.5 volt drop per output line within the limits of the output voltage adjustment range
  • Startup time: 800 mS typical
  • StorageTemperature: –40 to +85°C
  • Switching Frequency: 100 kHz (Typical)
  • Temperature Coefficient: ±0.02%/°C (Typical)
  • Thermal Protection: (Case sizes DN8, DN8A, DN6A) thermostat, self-resetting | (Case size DN6B) inherently protected
  • Transient response: 300 µS to return to ±1% of output setting | Maximum of ±3% output excursion following a load step change from 50% to 100%

 